Features:
- 4 oz. bowl
- manual drain
- high flow capacity
- can be filled under pressure
- To adjust and set oil delivery rate the unit must be pressurized and air must be flowing through the unit. Turn the sight dome, located on the top of the unit, counter clockwise to initiate oil delivery. The rate of oil delivery depends on air flow rate. If flow increases or decreases, the oil delivery rate will increase or decrease proportionally. Turning the sight dome clockwise will stop all oil delivery.
- maximum operating conditions:
- transparent bowl: 150 PSIG (10.3 bar) and 32°F to 125°F (0°C to 52°C)
- metal bowl: 250 PSIG (17.2 bar) and 32°F to 150°F (0°C to 66°C)